›› 2011, Vol. 25 ›› Issue (4): 11-13.

Previous Articles     Next Articles

Application of Advanced I-steel Pile in Excavation Retaining

CHEN  Yi  quan1, LI  Xing  yuan2
  

  1. (1. Taian Urban Construction Design Institute, Taian Shandong 271000; 2. Shandong Luxin Investment Holdings Corp, Jinan 250014, China)
  • Received:2010-07-29 Online:2011-08-20 Published:2011-11-23

Abstract: For the excavation of garage foundation, its excavated depth is no less than 6.0 m and the distance between the excavation and the existing building is just 0.3 m. The crack in the building nearby is caused if the normal construction method is accepted, therefore the combination of advanced I\|steel pile with soil nail is adopted, the construction procedure is adjusted, which is successfully for the deformation control and the stability of around buildings.